To connect the flashing material to other building materials such as masonry concrete metal and wood.
Parapet height against sloped roof. On walls greater than 36 inches high membrane wall flashing sheets are suggested to be strapped i e installed vertically. A parapet wall is a low or dwarf wall built along the edge of the roof terrace walkway balcony etc. Sun 30 nov 2008 13 21 22 0800 say you have a small existing victorian wood building 30 x 22 12 ceiling with a 22 5 degree roof pitch 5 ridge height gable ends but 2 orthoganal walls have a 4 parapet 1 foot lower than the ridge the front gable end and one side have. Parapet walls can be constructed using different materials like reinforced cement concrete steel aluminium glass etc.
Exception to section 1730. To seal the juncture of the roof membrane with other building components such as walls edges and penetrations. This detail may be used where wall heights are 24 48 inches above roof surface. I somewhat agree that if the shape of the kickers matches that of the parapet that it may be the equivalent of a flat roof load.
The slope of the structure is roughly 25 degrees 4 tall and 8 long with 2 of vertical parapet sticking up above that. Yes i am looking at asce 7. Flashing application requirements are similar for all types of low slope roof materials and systems. Parapetitus they have a long history which of course is not always clear that allows me to embellish without threat of peer review reversal.
Where the roof slopes toward a parapet at a slope greater than two units vertical in 12 units horizontal 16 7 percent slope the parapet shall extend to the same height as any portion of the roof within a fire separation distance where protection of wall openings is required but in no case shall the height be less than 30 inches 762 mm. Different types of parapet walls and their uses are discussed below. Section 1731 applies instead of section 1730 for roofing work on new production type residential construction with roof slopes 3 12 or greater. Historically so many problems have occurred with parapets that we have a name for it.
The profile of specific components their. Overflow drains having the same size as the roof drains shall be installed with the inlet flow line located 2 inches 51 mm above the low point of the roof or overflow scuppers having three times the size of the roof drains and having a minimum opening height of 4 inches 102 mm shall be installed in the adjacent parapet walls with the inlet flow located 2 inches 51 mm above the low point. The height of parapets shall not be included in the roof height measurements. Parapets are a combination of wall and roof pressures.
1 their major function today aside from confusing architects is to protect the edge of roof assemblies from wind uplift forces. Wsrca suggests for walls 24 inches and taller that wall cladding be considered in lieu of membrane wall flashings per detail tp 8a.